eg4® 18kpv-12lv all-in-one hybrid inverter. Apr 20, 2023 · Hello. #1. 142156863 fault amps. Was charging at 70 amps, up to 56. In February 2023, EG4 announced a significant change to how their inverters do grounding and bonding. EPicTony said: I am building a off grid system using 2 EG4 6500EX-48 inverters in a 240vac split phase setup. The short greet CAT cable should be for connecting multiple batteries together. I ran a load test to drain the battery which it did. Feb 20, 2021 · Feb 10, 2024. With EG4 batteries we recommend the terminals be torqued to 6ft: lbs or 8nm If problem persists, contad your retailer. Options. 100 amps * . com/downloads/-----Please contact us at the link The EG4 6000XP is a cutting-edge 48V split-phase, off-grid inverter and charger, designed to revolutionize your energy needs. Inverter EG4 6500EX-48 User Manual. 5. I had a small space heater on low heat (about 800W), and switched it to high heat (1. Not running it all the time. I've had lead acid and outback equipment for 17 years so this is a big switch! I used to have 3 muffin fans positioned for extra cooling. Thank you for your assistance! 4. Upgraded features, when Feb 15, 2022 · ★ WIFI Model : Sungoldpower 6500W solar inverter built-in WIFI transmitter,Enable inverter data to be transmitted via WIFI to user's iphone or android smartphone, app can be downloaded from apple or android store ★ Batteryless support: 6500W 48V inverter can power the loads from PV array / ac grid without battery connected Dec 30, 2021 · After some quick online shopping, #4 copper THHN + conduit comes to about $1600, and 2-2-2-4 aluminum URD is about $475. Aug 1, 2022 · 144. Combining the capabilities of an inverter, MPPT solar charger, and battery charger, the 6500EX-48 All-in-One Solar Inverter offers uninterrupted power support in a single package. EG4® 6000XP . This sets the maximum utility charging voltage and the two trigger points for switching to the grid and switching back. When I woke up this morning I saw that the power in my house was out. Due to some odd behavior related to battery charging, I decided to upgrade the firmware on my inverters last night. Just a quick heads up, I have an EG4 6500EX-48 inverter and an EG4 three-battery rack for sale. signaturesolar. May 23, 2022 · Our thinking here was as follows: -Throwing away the combiner boxes and using half sized wire can save at least $1k on a 10+kW system (Plus time/labor) -The MC4 pv inputs are gone per NEC code for passing permit in most locations. I am still learning the ins and outs. The reason for this is/was to get off the pair of Honda generators that were supplying power to my RV. It's reading a dead short on the battery terminals to it Sep 24, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright May 6, 2023 · I am just setting up 2 EG4-6500EX-48's with a single Trophy 100Ah battery, and solar assistant on the way. The only source of power are PV panels. Order online today! This is from my new phone and I am just learning so things should get better. Two of my four batteries had to be removed from the battery bank because they got wet. Who does this affect: people with EG4 6k and 6. Yes I acknowledge. Jul 2, 2022. One of the advantages of a 48 volt inverter/charger in an RV is that only the buck converter needs to be close to the ac/dc distribution panel. com/?ref=countrylivingexperience HARVEST Sep 29, 2022. May 3, 2021 · Each of the PV inputs on this inverter have a Voc limit of 500V, and operating voltage of 90-450V. EG4® 6500EX 48 ALL-IN-ONE OFF-GRID INVERTER [LEGACY PRODUCT] - DOCUMENTATION - EG4 Electronics. Got the chargeverter in. Priority Reset PV If clicked, PV energy storage data will be reset. May 1, 2021 · Jun 4, 2022. 5k units Shipped after November first who are experiencing lights flickering when PV is Dec 23, 2019 · Make sure inverter button is in off position. I think it's an awesome entry-level inverte Innovative total emergency stop function for instant shutdown by RSD / ESS disconnect / inverter RSD; 10-year warranty offered by EG4 Electronics. Jul 2, 2022 · 143. 5hp worth of pumps starting at the same time could be as much as 20kW of surge. May 3, 2021 · I have two EG4 6500 EX inverters that have been working very well in parallel for the past 6 months. 101. The EG4 6000XP is a cutting-edge 48V split-phase, off-grid inverter and charger, designed to revolutionize your energy needs. Parallel up to 16 units for 96kWs worth of output power and control multiple stations and units using the new EG4 ® Jun 30, 2023 · In this video, I show the eg4 3kw inverter. View and Download EG4 3000 EHV-48 user manual online. 15kw Generac generator (to be purchased this week) just for one of the homes. Not with this model. The EG4 6000XP is a 48V split-phase off-grid inverter/charger that efficiently utilizes 8kW of PV and outputs 6kW of power while charging your battery bank. The EG4 6500 EX-48 is a residential self-consumption, multi-functional inverter/charger. I know the first time I attempted to do this, I had Shop Solar Sovereign's collection of all EG4 electronics. Also, it looks like the EG4 6500 terminals might not be big enough for 2 AWG, and aren't rated for AL/CU. eg4 ll 48v 100ah EG4 48V Indoor 280Ah WallMount Battery & EG4 6000XP Off-Grid Inverter Bundle 8000W PV Input | 6000W Output | All-In-One Solar Inverter. The scalable all-in-one off-grid inverter allows up to 16 units to be paralleled for 96kWs worth of power output. #2. 58. 5KVA 120V AC. I got the eg4 6500EX and the eg4 life power battery. Trouble right out of the box, I am Mar 14, 2024 · The EG4 6000XP is a 48V split-phase, off-grid inverter/charger with a built-in solar charge controller. 159. Experience 12 kW of continuous backup power, seamless generator integration, and enhanced PV pass-through. The comprehensive LCD display offers user configurable and easy-accessible Jun 7, 2023 · Download the firmware here:https://eg4electronics. com/eg4-6-5k-off-grid-inverter-6500ex-48/?ref=cPwLcVc0SW-BjNBudget Server Rack Battery: https://signature Meet any home's energy needs with EG4’s comprehensive portfolio of hybrid and off-grid inverters. Jan 25, 2024. Jun 17, 2022 · Jun 17, 2022. May 26, 2022 · Strictly off grid, the N-G bond should be in the inverter which is source. Been at it for over an hour. Skypower said: In SBU mode the inverters will run on Solar, then Battery. $5,412. Ethan from EG4 will be showing you guys how to get your EG4 6000EX-48HV 6000W Split Phase Off-Grid Solar Inverter up and running with EG4 Batteries! This vid Jan 4, 2020 · 143. May 24, 2022 · Signature Solar is proud to partner with EG4 Electronics in unveiling the TUV Certified EG4 6500EX-48 Inverter. 8 fuse headroom = 199. These items were recently purchased and installed and were used for about 2 weeks without any issues. I let them dry for hours, after which their alarm lights were cleared. 5kW Off-Grid Inverters. The inverter and main panel will be located only 3 feet apart. The EG4 6500 EX-48 stands as a residential self-consumption, versatile inverter/charger solution. 4v. View and Download EG4 6500EX-48 user manual online. $4,796. 31372549 service amps / . . They were connected to the charge controllers Jun 4, 2024 · 1. The EG4 6500EX-48 is considered an off-grid inverter and it functions as a load (like your toaster) when connected to the grid, and it is not possible to back feed to the utility. Total cost of wire would be about $205. Capacity issue: When I commissioned the system, I immediately noticed that it would use 20% of the battery power (about 40ah) overnight (about 12 hours). 6500EX 48 - Spec Sheet. Hello Everyone, would really appreciate any help with this problem: I am running a EG4 6500EX 48V Inverter, and noticing an odd issue where the incoming amperage to the PV1 input is being throttled. 61 version. Another newbie question. Can someone point me into what I need to run this off grid without shorting anything or destroying it. May 29, 2022 · @RichardfromEG4 are you referencing the rj45? Ive tried it both with and without the battery communication setup. 6kW of solar panels. Hello, I am waiting for my Eg4 6500 and Eg4 batteries to arrive, so I’m trying to get things ready but I have some questions. Do a search for filter guys wiring diagram version 2 for the eg4 and your situation. #22. Unless you install a 3 pole transfer switch before the main panel where neutral is switched, then it isn't truly off grid. Feb 1, 2023. OFF - GRID INVERTER . 120V/240V output direct from each unit! If you want 240V from the LV6548, you need to put 2X in series. Combining the capabilities of an inverter, MPPT solar charger, and a battery charger, the 6000EX-48HV offers uninterrupted power support in a single package. 85 conversion factor * 48 volts low cutoff = 4080 ac watts. Last week two batteries drained completely overnight, just red light flashing and 71! on my inverter. Yesterday the same happened again to the same two batteries, all other batteries May 24, 2022 · The inverter actually supports several communication protocols - and the 3 year warranty is still a year longer than most competitors for AiO's. This inverter is designed to the high specifications to meet or exceed UL1741 and CSA C22. I can get to the step of providing my Wi-Fi name and password but when going to the next step, the inverter cannot Jun 26, 2020 · Sulphur Springs, Texas. 1V and 478V for the entire string. Jul 18, 2022. Aluminum is looking attractive, but Signature Solar strongly recommends against using aluminum. When Solar is insufficient and Battery reaches back to grid setting (pgm12) it will switch to grid for load AND charge battery. Jul 1, 2022 · I have been testing the limits of my off grid solar system and have a question for the community/Signature solar on battery communication and charge settings. If you're using the S6U you'll want to configure (and test) settings #11, 12 and 13 as well. There's no confusion with the green Mar 1, 2023 · This week I mounted the 200A AC service panel and wired up the AC output from my two EG4 inverters to the AC panel. 4kW of panels connected to PV1. Also, tripped off one of the three lifepower4s. All warning labels and nameplates on this inverter should be clearly visible and must not be removed or covered. Documentation Downloads Software Drivers Educational Material EG4 Monitoring Center EG4® USB Read/Write Cable View Downloads CH341_HL-340_Drivers EG4 Inverter Installation Full System Wiring And Tips! Off Grid Solar! OUR SOLAR EQUIPMENTCLICK HERE: https://www. After installing the new version I was impressed how quickly the switch was from grid \ battery and back again. 5kva 120v ac (75 pages) Inverter EG4 6000EX-48 User Manual. Jan 9, 2022 · Jan 28, 2023. Based on the core rectifier in popular 6000W split phase inverters, the 6000EX-48HV has undergone rigorous modifications to stand out as one of the highest performing 6000W 120V/240V Split Phase Off-Grid Inverters on the market. I have six brand new 320W (~40V/10A) panels from Renogy wired in three pairs of two (each pair in series). The 2P1 inverter's MPPT input "idles" around 285W until I interrupt the input, then it instantly increases to match Page 69 Ensure that all your battery's terminal connections are sufficiently tightened. switch on battery bank. Remove both grounding screws inside the inverter and make sure your grounds are only connected on either the input or output of the inverters not both. Say it's a cold sunny day at about 32F. With the only all-in-one, CSA-certified inverter. The EG4 6500 EX-48 is a residential self consumption, multi-functional inverter/ charger, combining the capabilities of an inverter, MPPT solar charger, and a battery charger to offer uninterrupted power support in a single package. May 29, 2022 · Yes, there is updated firmware on the website with links on how to install. Grid AC can be used by the inverter to charge batteries or pass thru to power loads, it cannot send AC backwards into the grid for NET metering or sell back purposes. 00. Hello, I just swapped my off-grid EG4 6500ex inverters over to two Victron Multiplus II 48v/5000kva inverters with a 450v/200A Solar Charger while utilizing 900ah of EG4 LifePower4 batteries with an EG4 Hub and two 300ah Big Battery Kong Elite batteries. I may add a second inverter at a later date. Adam De Lay said: The one on the right side of the video should be the one you use to connect the battery to your computer. Consult with your local AHJ (Authority Having Jurisdiction) before installing this product for any additional regulations and requirements for the area. 0, which is Trophy's suggested and the highest Mar 27, 2022 · That one would mean I'd have to run a lot of 6 gauge (or maybe even 4ga) wire between my inverter, main and sub panels. When building your system it is critical you ensure your VOC does not exceed the 500V limit of a 6500EX inverter or you will let out the magic smoke! (8) banks of 16s LiFePO4 BYD 260ah cells run on (8) Overkill 16s 100A BMS. The lightweight EG4-6500EX really doesn't have any meaningful surge in this context, so it may go beyond the DC side. Nov 12, 2021 · You can find this on page 40 of the 6500EX manual. Mar 3, 2023 · 2023-07-23. Energy Storage Start Time For The setting range of start charging time for AC charger is from 00:00 to Enable AC 23:00. the grid or a ge. Aug 16, 2023 · Oct 2, 2023. I have 2 EG4 6500EX in split phase connected to 12 Lifepower4 batteries. Has anyone looked into replacing the two fans (DA09225B12VH DC12V 1. This document describes what was announced and goes into Aug 9, 2023. But, this one, while using an extra hot wire, would only need 10 gauge wire, plus, I wouldn't have to get two of them to get 240V. 6. system is: two inverters configured split phase, each with 3. Messages. The Eg4 6500 has 2 pv inputs for a total of 8000 watts and 500 volts. The inverter setting #29 at 48. 6500EX-48 inverter pdf manual download. a single package. 85 inverter efficiency / 48 volts low cutoff = 159. The 2P1 inverter loses about an hour per day on its clock, the 2P2 inverter does not. Seamless Integration. If you need more output, you can put multiple LV6048's in parallel. Combining the capabilities of an inverter, MPPT solar charger Solar Supply Set solar power as priority to charge the battery or to power the load. Quality solar inverters, bifacial solar panels, complete solar kits, solar batteries. View and Download EG4 6000EX-48 user manual online. 60A 48V AC Battery Charger. My setup will be 1 eg4 6500ex 48 inverter and 3 eg4 batteries. The EG4 6500 EX-48 is a residential self consumption, multi-functional inverter/ charger, combining the capabilities of an inverter, MPPT solar charger, and a battery charger to offer uninterupted power support in. 05Amp) inside the EG4 6500EX-48 inverter to make it quiet? It seems, they are using 4-pin PWM type fans (see attached photo) and I could replace them with Noctua quiet fans but Noctua fans draw little power compared to the fans inside the inverter drawing Jul 15, 2023 · #solar #diy #battery Today we connect the eg4 inverter and eg4 battery to show off how it works May 24, 2024 · I got one of my solar PV arrays completely wired up to the EG4 6500EX 48V inverter and tested the voltage to see if the inverter would turn on. Location. The 2p1 inverter seemed normal. I have them wired up, 5 400 watt panels to each inverter. What sets it apart is its scalability – you can parallel up to 16 units for an Jun 17, 2022 · I had a F06 code today on my single 6500EX inverter. 6500EX 48 - MANUAL. #8. I finished setting up the EG4 6500 and connected one battery for a mock setup. Dec 15, 2022 · EG4-6500 losing clock and MPPT issues. The EG4 6500EX-48 stand out as one of the highest-performing 6500W 120V, Split Phase Capable, All-in-One Off-Grid Inverters on the market. com/?ref=countrylivingexp Aug 8, 2023 · Aug 9, 2023. My inverters will be connected in 180 deg 3. EG4 6500EX 48V inverter and tested the voltage I wanted to try and do a little walkthrough on how to set up the WiFi and WatchPower app for the 6500s. The 6000XP is a 208/240 VAC split-phase, 48 VDC off-grid inverter/charger capable of utilizing 8kW of PV and efficiently outputting 6kW of power while also charging the battery bank. I started with three(3) EG4 Lifepower 48v 5kW batteries and after a month of little to no sun I have upgraded to six(6) EG4 Lifepower 48v 5kW batteries. Ideally, I would prefer local pick-up in Guadalajara or shipping. eg4® ll-s 48v 100ah lithium iron phosphate battery. #1 - Attempted to install the SolarPower application (from CD that came with EG4 6000EX-48HV inverter) onto my Windows 11 laptop but the install failed. I'm going to be running some more tests and showing more videos of this in parallel and I'll definitely test the N-G bond in all configurations. Having an inverter 48->12 volt buck converter is actually kind of awkward though. I currently have 4 arrays (11. -The EG4 battery comms are native. 2 requirements, and has been engineered to meet all the features that we hear our customers want. 25%/C this would push the Voc of each panel up to about 53. There are 4 terminals at the ac output, Hot 1, Hot 2, Neutral and Ground. Today was a bright, virtually cloudless day, temps about 50F and the time was about 2pm. Jul 20, 2022. Mexico. Hello Ben, I encountered two challenges with EG4 software/firmware. This all-in-one solar inverter amalgamates the functionalities of an inverter, MPPT solar charger, and battery charger, delivering uninterrupted power support within a single unit. 3000 EHV-48 inverter pdf manual download. In May 24, 2022 · 3. Signature Solar Signature Solar Nov 15, 2023 · My system consists of 2 eg4-6500ex's in split 240v, 6 eg4 lifepower 4's, 16 Q Cell panels(400 watts), and 16 Boviet panels (370watts). Oct 7, 2022. Turned on the two inverters, it did it's poweron thing, then just as they were about to output, one of them immediately popped the battery breaker for it, 100A. Say I have 9 bifacial panels with a Voc of 50V. 6kW) and it shut down and gave me the F06 code. Turn on 1st battery in the bank. 6500 EX-48 inverter pdf manual download. 5KVA 120Vac. Jun 13, 2022 · 9. I am planning to use only 120 V appliances in my cabin and I purchased one EG4 6500EX-48 for this purpose. 31372549 service amps. Appreciate your help. Feb 10, 2023 · So basically update your inverters to the stationary / cabin firmware. Jul 24, 2022. Additionally, it can be controlled using the new EG4 monitoring software. The AC input connection from the main panel is one way. Again this is just a test setup and is off-grid. I have x12 240w panels outside. There is not any reason to do it different. Jun 6, 2024. The system has been up and running without issue since July 22 of this year. Upgraded features compared to the competition include a 500VOC/8000W max SOLAR INVERTER/CHARGER 6. My system doesn't have batteries, but it does have 3. certifications. -Warranty repair and parts based in Texas. Please keep children away from touching or misusing the inverter and relevant The EG4 6000XP is a cutting-edge 48V split-phase, off-grid inverter and charger, designed to revolutionize your energy needs. MANUAL TUV/CSA Certificate Description The 6500EX-48 is the easiest way to get started on your next off-grid projects. e. Signature Solar provides solar panels, off-grid solar systems, grid-tie, and hybrid systems. Solar inverter/charger 6. However, you do have a grid supply. 4. Mar 20, 2022 · The EG4 6500EX is an OFF-GRID type inverter. The inverter and system can inter-connect with the utility grid only if the utility provider permits. Mar 31, 2022 · Aug 10, 2023. Overall, these changes allow for much greater flexibility in installing the inverter in ways that are both supported and meet the NEC requirements for grounding and bonding. Additionally 2X of the EG4 are going to consume around 40% of your total battery capacity just by Jan 24, 2024 · Tennessee. Hi All, So I've bought - and will soon assemble - the following equipment for two off-grid setups (two different homes): 4 EG4 6500ex-48 inverters. 5 inverter and the panel strings hooked up. Separate load center for this setup isolated from my May 29, 2022 · 376. All warning labels and nameplates on this inverter should be clearly visible and must Dec 23, 2021 · Offgrid 48V Solar System Blueprint Grid Interactive and Inspection Approved 48V System Solar System Component EG4 6500ex-48 All in One Inverter/Charger for sale. Make sure all 3 batteries are OFF. I've recently started getting Fault Code F11 on one of my two EG4 6500EX inverters. I just got my 2 WP eg4 48v batteries connected to my EG4 6. That makes a total of 450Voc. Aug 14, 2022. The inverter with a rack is priced at $1200. Also got Solarever 445W Split-Cell Mono Solar Panels 445w x6. This inverter will be connected directly to my main load panel and I have questions about this simple layout. It boasts the ability to take in 8kW of PV power and efficiently deliver 6kW of power, all while charging your battery bank. This page will constantly be updated with the newest manual and firmware for all of our products for you to utilize. A LITTLE BACKGROUND (not necessary reading): My system consists of two EG4 inverters (6500ex-48) and two banks of EG4 Lifepower4 48V 6000EX-48HV All-In-One Off-Grid Inverter [Legacy Product] The 6000EX-48HV is a residential self-consumption, multi-functional true split phase inverter/charger. Need info on doing a 48v off grid system. You can parallel up to 16 units to achieve an impressive 96kW of output power and control multiple stations and units Jun 27, 2022 · Uploading this quickly after working with our engineering team to show the proper way to communicate using multiple EG4 6500EX-48 6. That appears to change settings #12 & #13 to SOC percentages. PNW_Solar_Guy said: Aside from the cable size, it would seem that a good way to connect our battery bank to the two separate inverters would be to take the + cable from the top battery and the - cable from the bottom battery and connect those to Inverter #1; then connect the - cable from the top battery and the + cable from Oct 31, 2022 · I have two EG4 6500EX and so far they have been fairly bullet proof. May 23, 2022 · EG4 6500EX (affiliate link): https://signaturesolar. The 6000EX-48HV is a residential self-consumption, multi-functional true split phase inverter/charger. When I downloaded the firmware it appears there's a new 79. With a panel Voc Tc of -0. This collection includes EG4 Battery and EG4 Inverter. Can pair with any hybrid or off-grid inverter in the market; Designed to pair seamlessly with EG4, Victron, Growatt, Megarevo, Luxpower, Deye, and Sol-Ark inverters Jan 16, 2020 · Offgrid 48V Solar System Blueprint Grid Interactive and Inspection Approved 48V System Solar System Component EG4 6500ex-48 All in One Inverter/Charger for sale. When grid power is lost, your inverter could get its input power from the solar panels or batteries (for feeding its output loads) or you could Oct 7, 2022 · Joined. The installer should consider the safety of future users when choosing the inverter’s correct position and location as specified in this manual. Feb 10, 2023. With an impressive 8kW of PV input capacity and an efficient 6kW continuous power output, it also serves as a battery 140A charger. Aug 30, 2022 · I am using EG4-LL batteries, so setting #5 on the 2P1 is set to EG4. 5kva 120v ac (75 pages) Oct 10, 2022 · My panels are not hitting the ideal voltage values labeled on them. I was spending upwards near $40/day in fuel using the a/c to keep the RV at a remotely tolerable Eg4 Inverter Review! 6500EX vs Growatt Key Differences! OUR SOLAR EQUIPMENTCLICK HERE: https://www. Software / Drivers We are dedicated to ensuring that you will always have access to the most up to date information at all times. The batteries can only deliver about 5000W each. I have x2 48v 100ah eg4 lifepower4 batteries and x2 3kw all in one inverters running split phase. view downloads. Dec 7, 2021 · EG4 6K Off-Grid Split Phase Inverter | 6000EX-48HV | 6000W Output | 7500W PV Input | 500V VOC Input | Split Phase 120/240VAC | All In One Solar Inverter. #4. But both times im getting 61 UPDATE: after reversing the RJ45 cable and plugging into the inverter the end that has the eg4 sticker and only has 3/5 wired up the inverters been running now for 20m without a fault! Cool inverter with very similar transfer switch optimized for 50A RVs. I'm also confused about the AC input function. It sounds like my battery firmware version may need be reviewed/updated, next. Simply plug your inputs, batteries, and optional AC inputs (i. It says 4g or 6g wire but nothing on the size of the protective CB. I pulled them, charged them up completely and reinstalled. You battery has a maximum discharge rating of 100 amps (30 recommended). The 6500EX-48 will Act as your main hub for all your off-grid needs. The WallMount Indoor 280Ah batteries are ideal for low-voltage residential indoor energy storage ap. I have an EG4 battery bank 30kwh. Model EG4 6500EX-48 - Inverters. I plan to keep it as backup if needed. Aug 6, 2023 · For starters, I have a single EG4 6500Ex-48 inverter that is connected to (3) EG4 LL batteries. Like $400 worth. I was using the USB to CAT cable to try and hook up to the inverter. The 5 year warranty blows everyone else out of the water. We are releasing a firmware update on our website and here in this post that resolves the flickering light issue on the most recent batch of EG4 6000 and 6500 inverters. I give some tips on how to install it, as well as load test the unit. Feb 9, 2023. Observe battery startup sequence as well as clicking sound indicating pre-charge occurring, 4 green LED’s cycle then turn off and Red LED turns on solid. I went to my battery/ inverter room and saw that the 2p2 inverter was alarming and the LED band was red and an F90 code was displayed. I ordered two EG4 6500 so I could run 240v. 36 455W panels (9s each going to one inverterno combiner) 6 (soon to be 12) EG4 48v batteries. I know it’s a royal pain to get the Wi-Fi to work / connect on the EG4 6500. 5kw) feeding the solar charger. I can not seem to find what size the AC input CB should be. You need to be sure that you don’t exceed maximum input current (load + charge). Inverter / charger (53 pages) Sep 11, 2022 · John Frum said: 6500 ac watts / . yn eh vq jn mh wl pd wy tx um